top of page
Reliance | Jerguson | Jacoby-Tarbox | Oil Filtration Systems | Enervac | Anderson Separators | Anderson HYCOA | Anderson Filter Elements | Ernst Instruments | GPI Meters


Solving Challenging High-Temperature Applications in the UAE
A refinery in the UAE faced ongoing challenges with their Magnetic Level Gages and associated Level Switches. The high-temperature process within their columns caused boiling inside the gages, leading to unreliable readings and frequent false trips and alarms. Boiling fluids can cause the float to sink in a traditional level indicator. This situation is common when there are substantial temperature differences between the fluid in a vessel and the fluid in an indicator chambe
Mar 26, 20252 min read


Innovative MLI Solution for a Southeast U.S. Refinery
We recently tackled a unique challenge at a refinery in the Southeast United States with an application for magnetic level indicators, each spanning an impressive 300” center-to-center. The customer wanted to utilize the internal retention spring, but also wanted the ability to mate their process piping on the drain, as well as keep a standard side connected gage. This was necessary for a number of reasons, but the most prevalent being support. The customer has quite a few
Dec 11, 20241 min read


Custom-Engineered Instrumentation for Cooling Skids at an Air Separation Plant in the Southern U.S.
A custom engineered instrumentation solution is heading to an air separation plant in the Southern United States! These cooling...
Dec 6, 20241 min read


Series 5005 Sight Windows with Optional Spray Rings - Midwest Refinery
In a Midwest U.S. refinery, Jacoby-Tarbox's Series 5005 Sight Windows are making waves with their robust design and high-temperature capabilities. These sight windows are equipped with quartz, offering exceptional durability in extreme conditions. One standout feature is the purge port , allowing operators to cool the front of the window using nitrogen or other gases. This protective mechanism shields the window from excessive heat, ensuring both safety and longevity in dema
Dec 6, 20241 min read


Boiler Code Compliance in a California Refinery
Background A major refinery in California faced compliance challenges with the boilers in their hydrogen plant. The existing traditional ported gages were non-functional, leaving the facility in violation of the ASME Boiler Code. This posed both operational risks and regulatory concerns, necessitating immediate action to address the issue. Solution Our team, in collaboration with the local territory representative, conducted a comprehensive site survey to assess the plant’s r
Dec 5, 20242 min read


Solving Ice Build-Up in Cryogenic Level Measurement
Customer Challenge: A customer operating in a cryogenic environment relied on a prismatic glass gage to monitor liquid levels. However, ice frequently formed on the gage due to the extreme temperatures, completely obscuring the view (see righthand photo). To check the level, operators had to: Drain the liquid. Isolate the gage. Wait 3–4 hours for the ice to melt. Once reopened, the gage would only provide a clear reading for a few minutes before icing up again, causing signif
Dec 5, 20241 min read


Optimizing Lube Oil Blending with Tank Liquid Agitators
A lube oil manufacturer in Brazil faced long blending times, taking approximately 8 hours to mix lube oil with proprietary additives using mechanical mixers. This prolonged process limited production capacity and operational efficiency. Using AccuBlend Computational Fluid Dynamics (CFD) A Jacoby-Tarbox® Program™ , it was demonstrated that Tank Liquid Agitators (TLAs) offered a more efficient mixing solution. The analysis revealed that in-tank eductors could achieve the same b
Dec 2, 20241 min read


Overcoming Low Specific Gravity Challenges with a Customized MLI Solution
The Problem: A major refinery in India faced operational challenges in their Refinery Off-Gas Cracker Plant for an Ethane Vapor application. The traditional magnetic level gage initially installed proved inadequate for the process due to the low specific gravity (SG) of 0.44. The gage's flags failed to rotate accurately, leading to incorrect level readings and frequent equipment malfunctions. The Jerguson Solution: We proposed and installed a Jerguson® Magnicator® Magnetic Le
Nov 25, 20241 min read


Jacoby-Tarbox Drop-In Spray Ring - Video Demo
DID YOU KNOW? Jacoby-Tarbox offers a full line of spray rings for installation directly against sight windows to direct secondary fluids (liquid or gas) against the window to remove debris. Standard Features: • Size Range: 2” through 10” • ASME Flange Class: 150, 300, 600 • “Ring” style centered by bolting • ¼” NPT Supply connection • Material: 316 SS • Maintains window rating • Compound angle radial and cross jets Optional Features: • Material: Corrosion resistant alloys •
Jul 9, 20241 min read


Jerguson Series 20™ Liquid Level Glass Gage - 77BL Safety Ballcheck Valves & Spring Washers - Refinery in the Midwest US
Check out this Jerguson Series 20™ Liquid Level Glass Gage, equipped with 77BL Safety Ballcheck Valves and Spring Washers, headed to a...
Apr 15, 20241 min read


Jerguson® Magnicator® Magnetic Level Indicator - Robust Construction Inside and Out
The Magnicator Indicator is connected to a process vessel. The chamber, or “column”, contains a sealed float with a permanent magnet...
Mar 19, 20241 min read


Don't Sacrifice Reliability When it Comes to Your Level Transmitter
PERFORMANCE AND RELIABILITY YOU EXPECT IN YOUR LEVEL TRANSMITTERS THE PROBLEM: Reliability issues with 'traditional' magnetrostrictive transmitters in terms of installation, setup, and connectivity. THE SOLUTION: With patent pending signal capture technology, the JMT™ Series Magnetostrictive Transmitter can be mounted on almost any chamber configuration without sacrificing reliability. The dual-entry enclosure allows for safe access to the HMI where information can be had wit
Mar 11, 20242 min read


Case Study: Wastewater and Process Water Solutions - Eductors
Utilizing eductors in wastewater and process water handling uses proven technology to maximize plant sustainability. Wastewater, often called process water, must conform to EPA regulations prior to returning it to the environment. Click here to read the full case study! Why Wastewater Handling Has Become a Bigger Conversation Chemical producers, refineries, and manufacturers - heavily regulated for gases and chemicals produced and added to the environment - are now being scru
Feb 27, 20243 min read


Refinery Lunch & Learn: Magnetic Level Indicator Training with Jerguson
We had Jerguson Product Manager - Magnetic Level Products, Robert Bolin, onsite at a major refinery in the Midwest US, giving a lunch & learn presentation on Jerguson Magnetic Level Products. Why We Do Lunch & Learns A lunch & learn puts real product expertise directly in front of the engineers, operators, and maintenance personnel who work with this equipment day to day - a different format than a webinar or a written article, since it allows direct questions and discussion
Sep 27, 20232 min read


Jerguson® Magnicator® Magnetic Level Indicator on a skid for monitoring & measuring turbo jet fuel
Check out our Jerguson® Magnicator® Magnetic Level Indicator installed on a skid for monitoring, measuring, and dispatching turbo jet fuel. This installation was for a skid manufacturer in Peru. The gages were inverted due to limited lower clearance - mounting them inverted allows operators to easily access the float from the top flange. How a Magnicator Actually Works The Magnicator level indicator connects to a process vessel. The chamber, or "column," contains a sealed flo
Sep 22, 20233 min read


500 Sight Flow Indicators Headed to a Midwestern Refinery for Upcoming Turnaround
We have our first batch of 1" Threaded Bulls-Eye Sight Flow Indicators (Model # 100-ST) headed to a major refinery in the Midwest United States. This refinery has ordered 500 Sight Flow Indicators total, to be included on the drain lines and connections of their tanks, ensuring all product is out of the tanks after a chemical wash during their next turnaround. Why Drain Line Verification Matters During a Turnaround A refinery turnaround involves taking process units offline f
Aug 29, 20232 min read


In-Tank Eductor Technology for Suspending Solids & Mixing: A Fuels Refinery in the Southern US
A fuels refinery in the Southern US contacted us regarding our in-tank eductor technology, Tank Liquid Agitators (TLAs). The tank at this refinery is used for crude oil received from a ship and then moved into the refinery for processing. Two Jobs, One Tank This application required the TLAs to do two things at once: suspend solids and mix the tank contents. Crude oil storage tanks commonly deal with basic sediment and water (BS&W) — heavier material that settles out of the o
Jan 19, 20233 min read


67LE Valves on a 4-Section Glass Gage: Shipment to a Major Midwest Refinery
We recently shipped three 4-section, glass series size 8, transparent close hookup series 20 gages (48TCH20) bridle assemblies with 67LE valves and illuminators to a major refinery in the Midwest. Continuing on our Low-E topic, these 67LE valves are low-emission certified to API 624, providing compliance with EPA standards (see our companion article on what API 624 testing actually involves). Understanding the Gage Designation The "48TCH20" designation packs several specifica
Jun 7, 20222 min read


Jerguson® Low-Emission Safety Ballcheck Valves: API 624 & LDAR Compliance
Power plants, chemical plants, and refineries have a large number of potential leak sources that can release harmful fugitive emissions (FEs) into the environment. This creates real risk on multiple fronts: environmental damage, exposure of plant personnel to harmful gases and vapors, and economic impacts from lost product. As a result, regulations are becoming increasingly strict, and many facilities are proactively requiring that any valves procured for future maintenance a
Jun 2, 20223 min read


Maintaining a Minimum Safe Water Level Is Critical on Steam Boilers
Many low-pressure package boilers use tubular glass gages as a means for monitoring level on their Low Water Cut Off/Pump Controllers. These boilers typically operate below 250 WSP (working steam pressure). It's a common setup — but tubular glass carries a risk that's often overlooked: it's susceptible to chipping or breaking, and as a result can be potentially unsafe even in these low-pressure steam applications. Why Low-Pressure Doesn't Mean Low-Risk There's a natural assum
May 10, 20223 min read
bottom of page
