top of page
Reliance | Jerguson | Jacoby-Tarbox | Oil Filtration Systems | Enervac | Anderson Separators | Anderson HYCOA | Anderson Filter Elements | Ernst Instruments | GPI Meters


Solving Clearance Issues with a Clever Magnetic Level Gage Install
Here’s a look at one of our Jerguson® Magnicator® Magnetic Level Indicators installed on a process tank at a chemical processing facility. You’ll notice something different—this gage is inverted. The gage is inverted due to limited lower clearance. The gage being inverted allows the operators to easily access the float from the top flange. This magnetic level indicator is also equipped with SAS-16™ Snap-Action Switches. SAS-16 Switches can be used as a low, low-low, high, or
Apr 9, 20251 min read


Improving Safety and Reliability with Jerguson Magnicator Magnetic Level Gages
A petrochemical facility in the Caribbean recently enhanced the safety and efficiency of its operations by replacing their traditional...
Dec 5, 20241 min read


Continuous Level Monitoring Solution for an Agrochemical Manufacturer in India
An agrochemical company in India required a 0-100% level output in the control room for continuous monitoring of their Magnetic Level...
Dec 5, 20242 min read


Enhancing Level Visibility for a Chemical Company in Chile with Simpliport® 180 Bi-Color Ported Water Gages
Background A chemical company in Chile struggled with poor visibility on its bicolor gages. These gages utilized multiple layers of mica...
Dec 5, 20241 min read


Enhancing Efficiency with Eye-Hye® SmartLevel™ Remote Water Level Indication System in a Chemical Plant
A small chemical plant faced challenges with inconsistent readings from Differential Pressure (DP) transmitters used for drum level...
Dec 5, 20241 min read


Jerguson® Magnicator®: Schedule 80/160 Magnetic Indicators - Robust Construction Inside and Out
The Magnicator Indicator connects to a process vessel. The chamber, or "column," contains a sealed float with a permanent magnet assembly which rises and falls as liquid level changes in the process vessel. The permanent magnet assembly in the float is magnetically coupled to an indicator, mounted externally to the gage column but completely isolated from the process liquid. Indicator flags are rotated by the float magnet assembly as it moves up and down in the chamber, provi
Mar 19, 20243 min read


Don't Sacrifice Reliability When It Comes to Your Level Transmitter
Performance and reliability are what you expect in a level transmitter - but traditional magnetostrictive transmitters have long been associated with reliability issues around installation, setup, and connectivity. The Jerguson® JMT™ Series Magnetostrictive Transmitter was engineered specifically to solve this. The Problem with Traditional Magnetostrictive Transmitters Reliability issues with traditional magnetostrictive transmitters typically show up in three places: install
Mar 11, 20243 min read


Jerguson® Magnicator® MGWR™: Dual Chamber Redundant Level Measurement
Check out this Jerguson® Magnicator® with Guided Wave Radar (MGWR™) - Dual Chamber configuration, headed to a specialty products manufacturer in Louisiana. Dual Chamber vs. Single Chamber MGWR We've covered the single-chamber MGWR design elsewhere, where a slotted internal baffle plate separates the float and GWR probe within one compact chamber. The dual-chamber configuration takes a different approach: rather than sharing one chamber with an internal baffle, the Magnicator
Dec 18, 20232 min read


Magnicator® Quick Ship Program Saves the Day at a Chemical Company in the Gulf Coast
We recently had a chemical manufacturer reach out to us to retrofit their dated transmitter with one of our Jerguson® JMT™ Series Magnetostrictive Transmitters. After the install, the customer reported weak magnetic strength while testing their existing float. They decided to retrofit their entire gage to a Jerguson® Magnicator® Magnetic Level Indicator. The customer utilized our Magnicator® Quick Ship Program, receiving the new magnetic level indicator in 48 hours. How a Tra
Nov 6, 20232 min read


Unreliable, Dated Technology Replaced with a Jerguson® Level Gage with LumaStar™ LED Illuminator
A chemical manufacturing company in Texas came to us with a specific need: replace unreliable, dated technology. They wanted their tubular boiler gage with fluorescent lighting replaced with a Jerguson® Armored Level Gage assembly featuring a Jerguson® LumaStar™ LED Illuminator (Model EPL-100). This glass gage assembly was for the facility's Waste Heat Boiler, operating at 120 PSI with a 200 PSI design condition. Two Separate Upgrades in One Project This replacement addressed
Sep 5, 20232 min read


Jerguson® Magnicator® + JMT™ Magnetostrictive Transmitter: Sold to an Engineering Firm in Brasília
A Jerguson® Magnicator® Magnetic Level Indicator paired with a JMT™ Series Magnetostrictive Transmitter was recently sold to an engineering firm in Brasília, Brazil — with another order already underway. The JMT was specified in a Schedule 160 chamber configuration with HART® communication, and it's worth explaining what makes this particular transmitter technology stand out. What Is a Magnetostrictive Transmitter? A magnetostrictive transmitter is a precision level-sensing t
Aug 17, 20223 min read


Jerguson® Low-Emission Safety Ballcheck Valves: API 624 & LDAR Compliance
Power plants, chemical plants, and refineries have a large number of potential leak sources that can release harmful fugitive emissions (FEs) into the environment. This creates real risk on multiple fronts: environmental damage, exposure of plant personnel to harmful gases and vapors, and economic impacts from lost product. As a result, regulations are becoming increasingly strict, and many facilities are proactively requiring that any valves procured for future maintenance a
Jun 2, 20223 min read


Improve Profits & Achieve Sustainability Goals Through Better Mixing
Jacoby-Tarbox Product Manager Dave Purcel covered this exact topic in a session on how better tank mixing directly connects to both profitability and sustainability goals in chemical and industrial facilities. The core message: mixing isn't just a process step — it's an area where hidden costs and missed opportunities often go unnoticed. Let Compliance Lead to Profits Environmental compliance is often treated purely as a cost center — something facilities do to avoid penaltie
Jun 1, 20223 min read


3" Tank Liquid Agitators (TLAs) going to a chemical plant in the Gulf Coast
We recently shipped two 3" Tank Liquid Agitators (TLAs) to a chemical plant in the Gulf Coast. The Jacoby-Tarbox TLA is an eductor designed for "in-tank" applications — and it's addressing a challenge that's become increasingly important across the chemical and petroleum industry. How Tank Liquid Agitators Work Eductors require no power, which means no moving parts. The design of the eductor creates a pressure differential that allows fluid to flow naturally within the device
May 26, 20222 min read
bottom of page
