Adding an Illuminator to Existing Gages in the Field
- Nov 2, 2021
- 3 min read
Updated: Aug 6
If your facility has older gage glasses or level indicators installed in dark areas or locations with poor ambient lighting, you don't need to replace the entire gage. You can retrofit it with a modern LED illuminator to dramatically improve visibility. Here's what you need to know about adding illumination to existing equipment.
The Problem with Dark Gage Locations
Many facilities have gages installed in boiler rooms, control rooms, or outdoor areas where natural or ambient lighting is inadequate. Operators struggle to see water level clearly, especially at night or in overcast weather. This creates safety and operational issues:
Difficult Reading: Operators must stand very close or use flashlights
Operator Error: Poor visibility leads to misreading levels
Safety Risk: Operators exposed to hot equipment trying to see better
Equipment Wear: Operators tap or vibrate gages trying to confirm readings
Replacing the entire gage is expensive and time-consuming. Retrofitting with an LED illuminator is the practical solution.
LED Illuminators vs. Incandescent
Old Incandescent Style:
Service life: 1,000-2,000 hours continuous use (about 3-6 months)
Generates significant heat
Requires frequent replacement
High operating cost
Unreliable in vibration-prone areas
Modern LED Illuminators:
Service life: 100,000+ hours continuous use (10+ years)
No heat generation
Virtually maintenance-free
Low operating cost
Superior visibility regardless of ambient light
LED technology makes retrofitting practical because you won't be changing illuminators every few months.
The Jerguson EPL-100 LumaStar™ LED Illuminator
The EPL-100 LumaStar™ is specifically designed as a universal retrofit solution. Key features:
Universal Compatibility
Fits Jerguson gages and most competitor models
Accommodates gage cover widths up to 3-1/2 inches
Universal bracket design adapts to most existing installations
No gage modification required
Superior Light Output
White LED cuts through process fluids (water, oil, chemicals)
Exceptional visibility even in bright sunlight or dark areas
Adjustable brightness on some models
Consistent light output over entire service life
Low Maintenance
100,000+ hour service life (10-15 years typical)
No replacement bulbs needed
Sealed design withstands moisture and vibration
Single power connection
Cost-Effective
Fraction of gage replacement cost
Quick installation (minimal downtime)
Low power consumption (operates on standard AC voltage)
Long service intervals reduce maintenance headaches
Installation Overview
Adding an LED illuminator to an existing gage is straightforward:
Step 1: Mount Bracket The universal bracket attaches to the gage cover using existing mounting points. No drilling or gage modification required.
Step 2: Position Light Source The LED light source positions to illuminate the gage glass from behind or to the side, depending on gage type.
Step 3: Connect Power Electrical connection to site power (typically 120VAC or 240VAC). Most installations require standard electrical conduit.
Step 4: Test and Adjust Verify illumination and make minor brightness adjustments if available.
When to Retrofit vs. Replace
Retrofit with LED Illuminator if:
Gage is functioning properly
Main issue is visibility/lighting
Existing gage is appropriate for the application
Cost is a consideration
Replace the Entire Gage if:
Gage glass is damaged or continuously fogging
Seals are leaking
Gage can't meet current safety standards
Application requirements have changed
Applications Benefiting Most
LED retrofits are particularly valuable in:
Outdoor boiler installations (weather exposure)
Control rooms with variable lighting
Dark boiler rooms
24/7 operations (night shift visibility)
Remote locations where power is available
Next Steps